6.
This heater needs fresh air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety
shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and
Ventilation, pages 5 through 7. If heater keeps shutting off, see Troubleshooting, pages 15 through 17.
7.
Do not run heater:
·
Where flammable liquids or vapors are used or stored.
·
Under dusty conditions.
8.
Do not use this heater to cook food or burn paper or other objects.
9.
Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the
heater and replace any part of the control system and any gas control which has been under water.
10. Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
11. Operating heater above elevations of 4,500 feet could cause pilot outage.
12. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

QUALIFIED INSTALLING AGENCY

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment
shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation, or
company that either in person or through a representative is engaged in and is responsible for:
a)
The installation, testing, or replacements of gas piping or
b)
The connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is
familiar with all precautions required; and that has complied with all the requirement of the authority having
jurisdiction.
PRODUCT FEATURES
SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system.
The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off
the heater if there is not enough fresh air.
DUAL FUEL CAPABLE
Your Fireplace is equipped to operate on either Propane or Natural gas. The fireplace is
shipped from the factory ready for connecting to Propane. The fireplace can easily be
changed to Natural gas by having your qualified installer follow the instructions on page
9 & 10 and the markings on the fireplace.
LOCAL CODES
Install and use heater with care. Follow all codes. In the absence of local codes, use the
latest edition of The National Fuel Gas Code, ANSI Z 223.1, also known as NFPA 54*.
*Available from:
This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.
American National Standards lnstitute, lnc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, lnc.
1 Batterymarch Park
Quincy, MA 02269
4
State of Massachusetts: The
installation must be made by
a licensed plumber or gas
fitter in the Commonwealth of
Massachusetts. Sellers of
unvented propane or natural
gas-fired supplemental room
heaters shall provide to each
purchaser a copy of 527 CMR
30 upon sale of the unit.
In the State of Massachusetts,
unvented propane or natural
gas-fired space heaters shall
be prohibited in bedrooms
and bathrooms.
In the State of
Massachusetts the gas
cock must be a T-handle
type. The State of
Massachusetts requires
that a flexible appliance
connector cannot
exceed three feet in
length.