Wiring Rs-232 Console And Relay Output - Korenix JetNet 6710G Series User Manual

Industrial 8-port poe + 2 gigabit tx managed ethernet switch
Hide thumbs Also See for JetNet 6710G Series:
Table of Contents

Advertisement

2.3

Wiring RS-232 console and Relay Output

The RS-232 console and the alarm relay are connected via the assembly
type of 5-pole M12 A-coding connector included in the supplied package of
JetNet switch. The following figure 3-2-1 is the disassembly diagram of M12
A-coding connector.
Figure 2.3-1 Field Assemble M12 disassembly
In the M12 connector packing, the parts 1, 2, 3 are already assembled.
Follow the steps for soldering and assembling the cable and connector
together:
Step -1: Slide component 4, 5, 6 and then 7 over the
console cable. Keep them loose. Do not tighten them
yet. 2 cable glands are provided for cable diameter from
3.5 to 5.8 mm. Choose the one that best fits the cable.
Picture 8
Step-2: Solder the conductors with the copper wires according to the pin
assignment. The soldering side view of the pin is shown as below:
11

Advertisement

Table of Contents
loading

Table of Contents