step 3: assemble the cable

You will be attaching an outdoor-rated 24 AWG CAT5 cable (diameter .114
to .250 inches/2.9 to 6.4 mm) (not provided) to the Power-over-Ethernet
port on the back of the unit and weatherproofing the assembly later in the
installation procedure. First, you must construct the cable and assemble
the weatherproofing cable covers as described in the following steps. Proxim
greatly simplifies this assembly process by offering pre-assembled CAT5 cable
kits in 25m, 50m, and 75m lengths (part numbers 69819, 69820, and 69821,
respectively).
1.
Slide the sealing nut (A) over the bare end of the CAT5 cable.
2.
Slide the lock nut (B) over the bare end of the CAT5 cable.
3.
Slide the sealing cap (C) over the bare end of the CAT5 cable. Make sure
the red rubber gasket is inside the cap.
4.
Apply two wraps of 0.5" wide Teflon tape (not supplied with unit) around
the threads of the lock nut (B) that will go inside the sealing cap.
5.
Thread the lock nut (B) onto the sealing cap (C), and hand tighten.
6.
Terminate the RJ45 connectors (D) to both ends of the CAT5 cable; test for
proper wiring (using a straight-through cable).
Notes:
The cable must feed through all parts of the weatherproof cap before the
RJ45 is crimped on the outdoor Ethernet cable.
The cable between the power injector and the unit must be a straight-
through Ethernet cable (without crossover).
Due to variance in CAT5 cable diameter, termination techniques of the
installer, and the application of proper tightness of the connectors, it is
strongly recommended that all cable connectors are secured by external
weatherproofing. This process will be described in
the
Connectors.