CONTINUED FRAMING AND INSTALLATION
8. Center heater from left to right till flue exit of heater aligns with flue exit of 80ZC cabinet.
9. Lower the slip collar into flue exit of the heater by turning poisoning nuts counter clock wise
allowing slip collar to be lowered, push down and fit evenly until recessed in the flue exit opening.
Continue to lower bolts to a snug fit to hold slip collar in place.(See Figure 22)
10. Replace front on to 80ZC cabinet with the (6) six screws removed earlier. DO NOT TIGHTEN
SCREWS ALL THE WAY.
11. Place the front expanded screen, bent end toward stove and flat end between front of cabinet and
back of front. Slide front expanded screen against stove. Tighten the (6) six screws. (See Figure 23)
12. Install brass louver, the front has an 3 3/4" X 28 3/8" opening with (2) two holes in the top of the
opening. There are (2) two rods at top of louver. Insert louver rods into the (2) two holes in top of
3 3/4" X 28 3/8" front opening and slide the bottom of louver into bottom of opening.
(See Figure 23)
NOTE: At some point you may need to remove your Model 80 room heater from the Model 80ZC,
if so reverse steps 5-12.
SLIP COLLAR NUTS
FIGURE 22
SLIP COLLAR
FLUE EXIT