Installing 80Zv Cabinet, Optional Raised Base Installation - New Buck Corporation 80ZC Operation Maintenance Safety

Zero clearance cabinet for use with fireplace model 80 only
Hide thumbs Also See for 80ZC:
Table of Contents

Advertisement

CONTINUED FRAMING AND INSTALLATION
INSTALLING 80ZC CABINET WITH OPTIONAL RAISED BASE
WOODEN RAISED BASE
A wooden raised base constructed of plywood or 2" x 4" boards is required in order to get proper
clearance above the extended hearth (millboard, rock stone, etc.).
The base for the Model 80ZC must be level with or slightly higher than the "finished" hearth height
dimension (A) See Figure 13.
SAFETY SHIELDS
a. One (1) 6" X 47 1/2" sheet metal safety shield is supplied. Place 4" of shield under the raised base
under cabinet and 2" forward in front of unit, under the floor protector or finished hearth.
Attach 6" X 47 1/2" safety shield using sheet metal screws. (See Figure 11).
b. Purchase One (1) 24 gauge galvanized sheet metal safety shield to be bent and placed in front of
raised combustible base and placed under floor protector or finished hearth. The top of the bent sheet
metal safety shield must be the same height as the raised base and touching the bottom of 80ZC
cabinet. The rest of the safety shield is bent under the floor protector or finished hearth.
Attach bent safety shield using sheet metal screws. (See Figure 20).
NOTE: "Safety Shields for hearth extension must be used on installation."
DIMENSION
(A)
WOODEN RAISED BASE
1-B SAFETY SHIELD
1-A First safety shield for millboard hearth extension in front of raised base and under floor protector or
finished hearth extension
1-B Second safety shield for millboard hearth extension for optional raised base installation. Place (4")
four inches of safety shield under the raised base. Place floor protector or finished hearth extension on top
of safety shield.
FIGURE 13
SIDE VIEW
80ZC CABINET
6" X 47 1/2"
4" BACK FROM
FRONT OF UNIT
1-A SAFETY SHIELD BENT 90˚ SAME HEIGHT AS
RAISED BASE AND PLACED UNDER FLOOR
PROTECTOR OR FINISH HEART EXTENSION
4"
2"
2" FORWARD FROM
FRONT OF UNIT
Page 14
RAISED FLOOR PROTECTOR
OR FINISH HEART EXTENSION