CONTINUED FRAMING AND INSTALLATION
INSTALLING 80ZC CABINET FLAT ON THE FLOOR
Framing must be accomplished after the Model 80ZC is set in place. The chimney can be installed after
framing, but installation is considerably more difficult and in some cases, impossible. Therefore, it is rec-
ommended that the chimney be installed prior to framing when a choice exists.
POSITIONING 80ZC CABINET FOR INSTALLATION AS FOLLOWS
Thoroughly clean the area where the unit and hearth extension will be placed. Remove any carpeting/
padding from the area where the 80ZC cabinet will be installed.
1. Layout the location on the floor for the ZC cabinet .The structural integrity of the home, floor, wall
and ceiling/roof must be maintained. All so (See Page 9 Figure 5)
2. Now place the Model 80ZC cabinet in desired location.
NOTE: If a optional raised base is to be installed, see OPTIONAL RAISED BASE (Page 14).
SAFETY SHIELD
One (1) 6" X 47 1/2" sheet metal safety shield is supplied, place 4" under the cabinet and 2" forward
in front of unit, out under the floor protector or finished hearth. Attach 6" X 47 1/2" safety shield
using sheet metal screws. (See Figure 11).
NOTE: "Safety Shield for hearth extension must be used on installation."
1-A Safety shield for millboard hearth extension for flat on the floor installation. Place (4") four inches of
safety shield under the ZC Cabinet. Place floor protector or finished hearth extension on top of safety
shield.
FIGURE 11
SIDE VIEW
80ZC CABINET
1-A SAFETY SHIELD
6" X 47 1/2"
4" BACK FROM
FRONT OF UNIT
4"
2"
2" FORWARD FROM
FRONT OF UNIT
Page 12
FLOOR PROTECTOR OR
FINISH HEART EXTENSION