2.6.2. Interpretation of the program tables: symbols and values.
SYMBOL OPTION
Ph
1
L
2
3
C / F
0
1
d
2
3
4
1
r
2
3
rt
c
0
1
rh
0
1
1
E
2
4
6
Et
- - - -
Estimated program time
Minimum program time based on a machine with hot water supply and without
heating. Time in minutes.
Phase number.
The phase indicated with grey background belongs to the wash phase.
Bath level
Low level
Medium level
High level (units with pumped drain, levels 2 and 3 are the same)
Bath temperature
Value in Centigrade or Fahrenheit degrees
Dosing
Phase without dosing
Pre-wash dosing
Wash dosing
Bleach dosing
Softener / neutraliser dosing
Drum rotation
Heavy-duty rotation: 25 sec. ON / 5 seconds stop.
Normal rotation: 15 sec. ON / 15 seconds stop.
Delicate rotation: 5 sec. ON / 25 seconds stop.
Rotation time
Value in minutes
Gradual cool down
Option non available
Option available
Program stop in the last rinse (rinse hold)
Option non available
Option available
Bath drain
Drain + wash speed
Drain + positioning speed
Drain + medium spin speed
Drain + high spin speed
Spin time
Value in minutes
Non programmable value in the phase
Operation
DESCRIPTION
15
Cod. 429266
Rev. 01/0206
Need help?
Do you have a question about the LOGI CONTROL and is the answer not in the manual?