3
Unplug the ac adapter from the power harness (see Figure 6). You can leave the ac adapter
plugged into the wiring harness.
4
Disconnect the molex connector leading to the gas control valve (see Figure 7).
WARNING: The tabs on the gas control valve are fragile. Take care when removing the molex
connector to not pull or damage the wires or tabs.
5
Disconnect the two leads on the back of the control panel for the IPI / CPI switch (continuous pilot
/ greensmart pilot – see Figure 8).