Stop Time
003
Specifies the time for measuring the nip.
1112
[Environmental Correction: Fusing]
Temp.: Threshold: Low
001
Specifies the threshold temperature for low temperature condition.
Temp.: Threshold: High
002
Specifies the threshold temperature for high temperature condition.
Low Temp. Correction
003 Specifies the temperature correction for the heating roller. When the low
temperature condition (specified with SP1112-001) is detected, the value of
this SP is added to the heating roller temperature.
High Temp. Correction
004 Specifies the temperature correction for the heating roller. When the high
temperature condition (specified with SP1112-002) is detected, the value of
this SP is subtracted from the heating roller temperature.
1113
[Stand-by Time]
After Ready
Specifies the interval from the ready mode to the stand-by mode.
001
If the machine does not do any printing job for the time specified with this SP
after the heating roller has reached the ready temperature, the machine
returns to the stand-by mode.
002 Recovery Target Temp.
After Recovery
003
Specifies the interval from the recovery to the stand-by mode.
If the machine does not do any printing job for the time specified with this SP
SM
* ENG
[5 to 30 / 10 / 1 sec/step]
*ENG
[10 to 23 / 17 / 1°C/step]
*ENG
[24 to 40 / 30 / 1°C/step]
*ENG
[0 to 15 / 5 / 1°C/step]
*ENG
[0 to 15 / 5 / 1°C/step]
*ENG
[0 to 60 / 10 / 1 sec/step]
*ENG
[0 to 60 / 10 / 1 sec/step] Not used
*ENG
[0 to 60 / 10 / 1 sec/step]
5-15