Optional Gas Line Location; Electrical Connection; Electrical Line Location - FireplaceXtrordinair 21 DV Manual

Built-in direct vent fireplace
Hide thumbs Also See for 21 DV:
Table of Contents

Advertisement

Installation
1 2

Optional Gas Line Location

Position the gas inlet assembly over the hole in
c
the baseplate (do not secure at this time).
Position the cover plate over the gas inlet hole on
the left side of the fireplace and secure using the
nuts removed in step "b".

Electrical Connection

Make sure the household breaker is shut off prior to working on any electrical lines.
The fireplace must be properly grounded in accordance with local codes (or ANSI/NFPA 70-1987)
The electrical line must be 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)

Electrical Line Location

Standard Location
Travis Industries
Remove the two screws near the
a
gas inlet (save these screws).
Phillips
Screwdriver
(for qualified installers only)
Remove the cover plate on the bottom
b
of the fireplace (save these nuts).
HINT: remove the
control cover for
easier access.
Secure the gas inlet assembly using
d
the screws removed in step "a".
Optional Location
The optional electrical inlet is flush
with the base of the fireplace.
1-3/4"
7"
NOTE: a 3-1/2" diameter hole is required to
provide clearance for the electrical inlet screws.
4030612
7/16" Wrench
Phillips
Screwdriver
5-3/8"
3-1/8"
1 0 0 - 0 1 1 4 3