Facing Requirements - FireplaceXtrordinair 21 DV Manual

Built-in direct vent fireplace
Hide thumbs Also See for 21 DV:
Table of Contents

Advertisement

Installation

Facing Requirements

NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it
does, it is considered a mantel and must meet the mantel requirements listed in this manual.
Facing Under 1" Thick
Any material that protrudes
more than 3/4" in front of the
facing is considered a mantel
and must meet the mantel
requirements in this manual.
NOTE: The facing tucks
behind the flanges.
Recommended Order of Installation We
recommend installing the facing (drywall, tile)
under the notch at the front of the fireplace
("a") - then install the sides and top ("b" and
"c")
Facing Over 1" Thick
Facing that protrudes in front of the face above the face (or within 1/2" of each side) must be made of
non-combustible materials.
N O T E A 3/8" gap above the face is required for face installation and removal.
Travis Industries
(for qualified installers only)
b
4030612
4-3/4"
3-3/8"
30-1/4"
(approx.)
c
a
NOTE The facing tucks under the notch at the front
of the fireplace (3/8" above the base of the fireplace).
2 1
The facing (combustible
or non-combustible)
must maintain a 1/2"
clearance to the sides
and top of the fireplace.
1 0 0 - 0 1 1 4 3

Advertisement

Table of Contents
loading

Table of Contents