Mantel Requirements - FireplaceXtrordinair 21 DV Manual

Built-in direct vent fireplace
Hide thumbs Also See for 21 DV:
Table of Contents

Advertisement

Installation
2 6

Mantel Requirements

The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it
is considered a mantel and must meet the mantel requirements listed below.
Use the table below to determine the maximum mantel depth allowed. For example, if a 6" mantel is
used, it must be a minimum of 6-1/2" above the face.
0" 1" 2" 3" 4" 5" 6" 7" 8" 9" 10" 11" 12"
9"
8"
7"
Mantel
6"
Height
5"
Above
4"
Face (a)
3"
2"
1"
0"
Travis Industries
Maximum Mantel Depth (b)
If you have a tapered mantel, measure the
mantel height at the point where it
protrudes 3/4" in front of the face.
(for qualified installers only)
b
a
35-3/8"