Facing Detail -Facing Over 1" Thick (Brick) - FireplaceXtrordinair 21 DV Manual

Built-in direct vent fireplace
Hide thumbs Also See for 21 DV:
Table of Contents

Advertisement

Installation
Facing Detail –Facing Over 1" Thick (Brick)
WARNING: Any facing that extends in front of the faceplate on the sides or top must be non-
combustible.
NOTE:
A 3/8" gap is required above the face for face installation.
Travis Industries
(for qualified installers only)
Top View
Fireplace
Face
Side View
Fireplace
3-d View
Wall Trim
The facing is brought up
to the wall trim.
4030612
NOTE: Make sure to leave a 1/8" gap
Framing
around the sides of the face and 3/8"
above (for face installation).
Drywall
1/4"
Non-combustible facing material (brick, stone,
1/8"
marble, tile) - required if the facing extends in
front of the face on the sides or top.
NOTE: Make sure to bring the facing up
to the wall trim.
In this example brick is used.
The side facing should be spaced 1/8"
from the face (3/8" from the flange on
the side stand-offs)
2 5
1 0 0 - 0 1 1 4 3