Gas Line Location; Converting Gas Line To The Left Side - FireplaceXtrordinair 864 TV 40K CleanFace Installation Manual

Hide thumbs Also See for 864 TV 40K CleanFace:
Table of Contents

Advertisement

Finalizing the Installation

Gas Line Location

NOTE FOR RIGID PIPE: When using rigid pipe, you may wish to disconnect the shutoff valve from the fireplace
and route the pipe through the fireplace wall. First, disconnect the gas line from the shutoff valve (see step 1
below). Then remove the shutoff valve from the cover plate (4 screws outside fireplace). The pipe may be routed
through the cover plate and the shutoff valve and gas line may be re-attached inside the fireplace.
Right Side Gas Line (Stock)
Left Side Gas Line
Framing
Opening

Converting Gas Line to the Left Side

ACCESSING THE AREA UNDER THE BURNER
If switching the gas line to the left side, see page 21 for accessing the area under the burner.
1. Disconnect the gas line from the shutoff valve (3/4" wrench). Gas line is located inside the fireplace
on the right side.
2. Remove the screw that holds the shutoff valve plate in place (1/4" nutdriver). Remove the shutoff
valve plate.
3. Remove the cover plate from the left side of the fireplace (it is held in place in the same fashion as
the shutoff valve plate). Attach it to the right side of the fireplace.
4. Attach the shutoff valve plate to the left side of the fireplace. Route the gas line to the left side and
re-attach the gas line to the shutoff valve. Make sure to leak test the entire gas line.
© Travis Industries
3" (77mm) Above Base
15 degrees
8.5"
216mm
(for qualified installers only)
7/18/2018 - 1481
3" (77mm) Above Base
15 degrees
11"
Framing
280mm
Opening
19
864 40K CF