Vent Requirements

The vent must maintain the required clearance to combustible materials to prevent a fire (see
"Clearances" below). Do not fill air spaces with insulation.
The gas appliance and vent system must be vented directly to the outside of the building, and never
be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas
appliance must use it's own separate vent system.

Altitude Considerations

This heater has been tested at altitudes ranging from sea level to 8,000 feet (2,400 M). In this testing we have
found that the heater, with its standard orifice, burns correctly with just an air shutter adjustment.
Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard.
Consult your dealer or installer if you suspect an improperly adjusted air shutter.

Vent Clearances

Min. 2" Clearance
Above the Vent
1/2" Clearance to the
front of vent before the
first firestop.
Part Numbers for 8" Diameter Pipe
Use Model GS Direct Vent manufactured by Simpson Dura-Vent only . Follow the installation
instructions included with the vent. For the nearest Simpson Dura-Vent supplier, call (800) 835-4429.
Vent part numbers and descriptions are listed below.
Straight Lengths
1208B
1207B
1206B
1204B
1203B
1202B
1211B
Black
Travis Industries
Use a firestop when passing
through any wall (WARNING:
some firestops provide a 1"
clearance above the vent -- 2"
is required for this heater).
0" Clearance to the
side of vent after the
first firestop.
6" Pipe Length, Black
9" Pipe Length, Black
12" Pipe Length, Black
24" Pipe Length, Black
36" Pipe Length, Black
48" Pipe Length, Black
11" to 14-5/8" Adjustable Pipe,
(for qualified installers only)
Min. 2" Clearance Above
45° Sloping Vent
Terminations
1285
Horizontal Square Termination
1291
Vert. High Wind Termination
1250
Vinyl Siding Stand-off
Elbows
1245B
45° Elbow, Black
1290B
90° Elbow, Black
4030612
0" Clearance to the sides
after the first firestop.
1" Clearance Below the Vent
Use a firestop whenever
passing through a
ceiling, enclosure or
floor penetration.
Penetration, Support
1242
Wall Firestop
1241
Cathedral Ceiling Support Box
1263
Ceiling Fire-stop
1288
Wall Strap
1 0 0 - 0 1 1 4 3