Optional Gas Line Location; Electrical Connection; Electrical Line Location; Optional Electrical Line Location - FireplaceXtrordinair 21 DV RV Manual

Built-in direct vent fireplace
Hide thumbs Also See for 21 DV RV:
Table of Contents

Advertisement

Installation (for qualified installers only)

Optional Gas Line Location

1/4" Nutdriver
Position the gas inlet assembly over the hole in the
c
baseplate and secure using the screws removed in
step "a" (NOTE: bend the flex tube as shown below -
this will ease in positioning of the gas inlet assembly).

Electrical Connection

Make sure the household breaker is shut off prior to working on any electrical lines.
The fireplace must be properly grounded in accordance with local codes (or ANSI/NFPA 70-1987)
The electrical line must be 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)

Electrical Line Location

Standard Location
Front of Fireplace
© Travis Industries
Remove the access cover on the
a
side of the fireplace.
10-1/2"
4040927
Remove the cover plate on the bottom
b
of the fireplace (save these nuts).
HINT: remove the
control cover for
easier access.
Secure the cover plate to the access cover with the
d
nuts removed in step "b". Secure the access cover to
the fireplace with the screws removed in step "a".
Optional Location
The optional electrical inlet is flush
with the base of the fireplace.
8"
NOTE: a 3-1/2" diameter hole is required to
provide clearance for the electrical inlet screws.
13
5/16" Wrench
10-1/2"
100-01158

Advertisement

Table of Contents
loading

Table of Contents