v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, System x3550 M3 Types 4254 and 7944," on page 159 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
v Go to the IBM support Web site at http://www.ibm.com/systems/support/ to check for technical
information, hints, tips, and new device drivers or to submit a request for information.
Error code
Description
00580A5
Mirror failover complete
00580A6
Spare memory channel activated
0068002
CMOS battery cleared.
2011001
PCI-X SERR
2018001
PCI Express uncorrected or uncorrected error 1. Check the riser-card LEDs.
Action
Information only. Memory redundancy has been lost.
Check the event log for uncorrected DIMM failure
events.
Information only. Memory online-spare channel has
been activated to back up a failed DIMM. Check the
event log for uncorrected DIMM failure events.
1. Reseat the battery.
2. Clear the CMOS memory (see "System-board
switches and jumpers" on page 18).
3. Replace the following components one at a time,
in the following order, restarting the server after
each one:
a. Battery
b. (Trained service technician only) System
board.
1. Check the riser-card LEDs.
2. Reseat all affected adapters and riser cards.
3. Update the PCI adapter firmware.
4. Remove the adapter from the riser card.
5. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Riser card
b. (Trained service technician only) System
board
2. Reseat all affected adapters and riser cards.
3. Update the PCI adapter firmware.
4. Remove the adapter from the riser card.
5. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Riser card
b. (Trained service technician only) System
board
33
Chapter 3. Diagnostics