FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 DIS/REASSEMBLY, ADJUSTMENT
98.04.13
Cleaning of the PC Drum Paper Separator Fingers
1174D002AA
Cleaning of the Ds Positioning Collars
1139D163AA
Cleaning of the Paper Dust Remover
1139D155AA
1139D156AA
Replacement of the Toner Antispill Mylar
1139D157AA
10. Using a soft cloth dampened with alcohol, wipe
clean the Paper Separator Fingers.
NOTE
Clean the Paper Separator Fingers carefully as its tip
is easy to bend.
11. Using a soft cloth dampened with alcohol, wipe
clean the Ds Positioning Collars.
12. Remove two screws, two compression coil springs
and the Synchronizing Roller Unit.
NOTE
When removing the Synchronizing Roller Unit, use
care not to lose the compression coil springs.
At reinstallation, fit the close-coiled end of the springs
to the bosses on the Imaging Unit.
13. Remove the Synchronizing Roller.
14. Using a brush, whisk the dust and dirt off the Filter.
15. Remove two screws and the Bias Seal.
(No Bias Seals are mounted in the copiers for the
U.S.A., Canada, and Europe.)
16. Remove two screws and the Toner Antispill Mylar
and replace the Mylar.
D-33