FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 MECHANICAL/ELECTRICAL
98.04.24
D The Start Key is pressed.
Start Key ON
ON
PC Drive Motor
ON
Main Erase Lamp
ON
Main Drive Motor
ON
Image Erase Lamp
All LEDs are turned ON.
ON
Developing Bias (High Voltage Unit)
ON
Paper Separator Corona (High Voltage Unit)
ON
Cleaning Bias (High Voltage Unit)
Some models have no Bias Seal installed depending on
their marketing areas.
ON
Synchronizing Roller Clutch
Approx. 0.3
Approx. 0.2
Approx. 0.2
Approx. 2.5
E Paper is taken up.
1st/2nd Drawer Paper Take-Up Solenoid ON
(2nd Drawer Paper Take-Up Solenoid: 23 cpm copier only)
ON
Approx. 0.4
1st Drawer:
Approx. 0.7
2nd Drawer:
Approx. 1.4
(23 cpm copier
Only)
1
For approx 0.2 sec. only
ON
1st/2nd Drawer Paper Take-Up Solenoid
OFF
Approx. 0.1
ON
PC Drum Charge Corona/Image Transfer Corona
ON
Paper Transport Clutch
ON
Synchronizing Roller Clutch
1st/2nd Drawer Paper Take-Up Sensor
ON
Transport Roller Sensor
ON
Approx. 0.5
ON
Approx. 0.2
M-9
1st/2nd Drawer Paper Take-Up
Solenoid (2nd Drawer Paper Take-
Up Solenoid: 23 cpm copier only)
Paper Leading Edge
Detecting Sensor
OFF
Approx. 0.2
Paper
Transport
Clutch
Exposure Lamp