Minolta EPI 054 User Manual page 240

Table of Contents

Advertisement

FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 SWITCHES ON PWBs/TECH. REP. SETTINGS
98.06.09
<Clearing Procedures>
• Initialize Points PJ2
1. Turn OFF the Power Switch.
2. With PJ2 closed, turn ON the Power Switch.
3. In approx. 5 sec., open PJ2.
• Memory Clear Test Point TP2
1. Turn OFF the Power Switch.
2. With the circuit across TP1 and 2 closed, turn ON the Power Switch.
3. In approx. 5 sec., open the circuit across TP1 and 2.
NOTE
• If an erratic operation or display occurs, perform the clearing procedures in the order of
PJ2 and TP2.
• When memory clear has been performed, make the necessary settings again.
<List of Data Cleared by Switches and Points>
Clearing Means
Data Cleared
Misfeed display
Malfunction display
(excluding Exposure
Lamp and fusing
malfunctions)
Malfunction display
(including Exposure
Lamp and fusing
malfunctions)
Erratic operation/display
User mode
Service mode
F3/5/8 adjustment values
Adjust mode
− : Not cleared
: Cleared
Trouble Reset
Front Door
Switch
Open/Close
(S1)
S-9
Initialize
Memory Clear
Points
Test Point
(PJ2)
(TP2)