To install a Remote Supervisor Adapter II SlimLine, complete the following steps.
Mounting bracket
retention latch
10. See the documentation that comes with the Remote Supervisor Adapter II

Hard disk drive

Locate the documentation that comes with the hard disk drive and follow those
instructions in addition to the instructions in this section.
Attention:
server cover is in place and fully closed whenever you install or remove a hard disk
drive.
Mounting bracket
Remote Supervisor
Adapter II Slimline connector
1. Put the protective plastic cover on the Remote Supervisor Adapter II SlimLine.
2. Turn the Remote Supervisor Adapter II SlimLine so that the keys on the
connector align correctly with the connector on the system board.
3. At a downward angle, insert the free end of the adapter under the tab on the
mounting bracket, aligning the holes in the adapter with the posts on the
mounting bracket. Rotate the rear of the adapter into the rear mounting
bracket, aligning the holes in the adapter with the posts on the rear mounting
bracket.
4. Press the Remote Supervisor Adapter II SlimLine firmly into the connector and
make sure that all tabs on both mounting brackets secure the adapter in place.
Attention:
Incomplete insertion might cause damage to the server or the
adapter.
5. Carefully align the riser-card assembly with the guides on the rear of the
server and with the riser-card connectors on the system board; then, press
down on the assembly. Make sure that the riser-card assembly is fully seated
in the riser-card connectors on the system board.
6. Install the cover (see "Installing the cover" on page 69).
7. Slide the server into the rack.
8. Connect the cables and power cords.
9. Turn on all attached devices and the server.
SlimLine for information about installing the firmware and configuring the
adapter. If you have a backup copy of the configuration, restore the
configuration.
To avoid damage to the hard disk drive connectors, make sure that the
Remote Supervisor Adapter II SlimLine
Rear of system
Chapter 4. Removing and replacing server components
Mounting bracket
73