IBM System x3250 Problem Determination And Service Manual page 30

Types 4364 and 4365
Hide thumbs Also See for System x3250:
Table of Contents

Advertisement

A single problem might cause more than one error message. When this occurs,
correct the cause of the first error message. The other error messages usually will
not occur the next time POST runs.
Exception: If there are multiple error codes or diagnostics LEDs that indicate a
microprocessor error, the error might be in the microprocessor or in the
microprocessor socket. See "Microprocessor problems" on page 28 for information
about diagnosing microprocessor problems.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 4364 or Type 4365 server," on page 59 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Beep code
1-1-3
1-1-4
1-2-1
1-2-2
1-2-3
1-2-4
1-3-1
2-1-1
2-1-2
2-1-3
12
IBM System x3250 Types 4364 and 4365: Problem Determination and Service Guide
Description
CMOS write/read test failed.
BIOS EEPROM checksum failed.
Programmable interval timer failed.
DMA initialization failed.
DMA page register write/read failed.
RAM refresh verification failed.
First 64K RAM test failed.
Secondary DMA register failed.
Primary DMA register failed.
Primary interrupt mask register failed.
Action
1. Reseat the battery.
2. Replace the following components one at
a time, in the order shown, restarting the
server each time:
a. Battery
b. (Trained service technician only)
System board
(Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the
system board.
1. Reseat the DIMMs.
2. Replace the following components, one at
a time, in the order shown:
a. DIMMs
b. (Trained service technician only)
System board
1. Reseat the DIMMs.
2. Replace the following components, one at
a time, in the order shown:
a. DIMMs
b. (Trained service technician only)
System board
(Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the
system board.