Checkout Procedure; About The Checkout Procedure - IBM System x3250 Problem Determination And Service Manual

Types 4364 and 4365
Hide thumbs Also See for System x3250:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 4364 or Type 4365 server," on page 59 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
I9990650
AC power has been restored.

Checkout procedure

The checkout procedure is the sequence of tasks that you should follow to
diagnose a problem in the server.

About the checkout procedure

Before you perform the checkout procedure for diagnosing hardware problems,
review the following information:
v Read the safety information that begins on page vii.
v The diagnostic programs provide the primary methods of testing the major
v When you run the diagnostic programs, a single problem might cause more than
v Before running the diagnostic programs, you must determine whether the failing
22
IBM System x3250 Types 4364 and 4365: Problem Determination and Service Guide
components of the server, such as the system board, Ethernet controller,
keyboard, mouse (pointing device), serial ports, and hard disk drives. You can
also use them to test some external devices. If you are not sure whether a
problem is caused by the hardware or by the software, you can use the
diagnostic programs to confirm that the hardware is working correctly.
one error message. When this happens, correct the cause of the first error
message. The other error messages usually will not occur the next time you run
the diagnostic programs.
Exception: If there are multiple error codes or LEDs that indicate a
microprocessor error, the error might be in the microprocessor or in the
microprocessor socket. See "Microprocessor problems" on page 28 for
information about diagnosing microprocessor problems.
server is part of a shared hard disk drive cluster (two or more servers that share
external storage devices). If it is part of a cluster, you can run all diagnostic
programs except the ones that test the storage unit (that is, a hard disk drive in
the storage unit) or the storage adapter that is attached to the storage unit. The
failing server might be part of a cluster if any of the following conditions is true:
– You have identified the failing server as part of a cluster (two or more servers
sharing external storage devices).
– One or more external storage units are attached to the failing server and at
least one of the attached storage units is also attached to another server or
unidentifiable device.
– One or more servers are located near the failing server.
Important: If the server is part of a shared hard disk drive cluster, run one test
at a time. Do not run any suite of tests, such as "quick" or "normal" tests,
because this might enable the hard disk drive diagnostic tests.
Action
1. Check the power cables.
2. Check for interruption of the power supply.