Error code
Description
1962
A hard disk drive does not contain a valid
boot sector.
5962
IDE DVD drive configuration error.
8603
Pointing-device error.
00012000
Processor machine check error.
20
IBM System x3250 Types 4364 and 4365: Problem Determination and Service Guide
Action
1. Make sure that a startable operating system is
installed.
2. Run the hard disk drive diagnostic tests.
3. Reseat the following components:
a. Hard disk drive
b. Hard disk drive backplane cable or back plate
cables
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. (Hot-swap models) Hard disk drive cable
b. Hard disk drive
c. Hard disk drive backplane or back plate
d. (Trained service technician only) System
board
1. Run the Configuration/Setup Utility program and
load the default settings (see "Using the
Configuration/Setup Utility program" on page
108).
2. Reseat the following components:
a. DVD drive cable
b. DVD drive
c. (Trained service technician only) System
board
3. Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
1. Reseat the pointing device.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Pointing device
b. (Trained service technician only) System
board
1. (Trained service technician only) Reseat the
microprocessor.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. (Trained service technician only)
Microprocessor
b. (Trained service technician only) System
board