v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 4364 or Type 4365 server," on page 59 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
035-002-0nn
ServeRAID interface timeout.
035-253-0nn
ServeRAID controller 0nn initialization
failure; 0nn = the controller number.
035-253-s99
RAID adapter initialization failure.
035-254-0nn
Setup error; unable to allocate memory to
run test.
035-255-0nn
Internal error.
035-260-0nn
System to controller interface failure.
40
IBM System x3250 Types 4364 and 4365: Problem Determination and Service Guide
Action
1. Make sure that the ServeRAID controller is
configured correctly. Obtain the basic and
extended configuration status bytes and see the
ServeRAID adapter Hardware Maintenance
Manual for more information.
2. Reseat the following components:
a. Hot-swap SAS/SATA hard disk drive
backplane cables
b. ServeRAID adapter
3. Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
1. The ServeRAID controller might not be configured
correctly. See the ServeRAID Hardware
Maintenance Manual for more information.
2. Reseat the following components:
a. Hot-swap SAS/SATA hard disk drive
backplane cables
b. ServeRAID adapter
3. Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
1. Reseat the following components:
a. ServeRAID adapter
b. Hot-swap SAS/SATA hard disk drive
backplane cable
2. Replace the components listed in step 1 one at a
time, in the order shown, restarting the server
each time.
Check the system resources and make more memory
available; then, run the test again.
1. Reseat the hot-swap SAS/SATA hard disk drive
backplane cable.
2. Replace the hot-swap SAS/SATA hard disk drive
backplane.
1. Reseat the following components:
a. ServeRAID adapter
b. Riser card
2. Replace the components listed in step 1 one at a
time, in the order shown, restarting the server
each time.