System Example 2, Id: 4605364_1009_01 - Viessmann VITOCAL 200-G Installation And Service Instructions Manual

Type bwc & bwc-m 201.a06 to a17, 6 to 17 kw single stage heat pump with electric drive, 400 v~ & type bwc-m 201.a06 to a10, 6 to 10 kw single stage heat pump with electric drive, 230 v~
Table of Contents

Advertisement

Preparing for installation
System example 1, ID: 4605363_1009_01
Parameter
DHW heating:
"Time program DHW"
"Time prog DHW circ"
For DHW reheating by booster heaters:
"DHW"
■ "Enable booster heaters for DHW heating
6014"
"Electr booster heater" (if installed)
"Enable instantaneous heating water heater
7900"
"Enable instant. heating water heater for cen-
tral heating 7902" if required
"Output for instant. heating water heater at
power-OFF 790A"
"Solar"
"Type solar control unit 7A00"
Remote control:
"Heating circuit 1"
■ "Remote control 2003"

System example 2, ID: 4605364_1009_01

Selecting system scheme 6
■ 1 heating circuit without mixer (A1)
■ 1 underfloor heating circuit with mixer
(M2)
■ DHW heating with solar backup
■ Heating water buffer cylinder
■ Natural cooling function at heating cir-
cuit M2
24
(cont.)
Setting
Set time program (see operating
instructions)
Set time program (see operating
instructions)
"1"
"1"
"1"
■ "1" for 3 kW
■ "2" for 6 kW
■ "3" for 9 kW
■ "1" (with Vitosolic 100)
■ "2" (with Vitosolic 200)
"1"
Note
This scheme is a general example with-
out shut-off valves or safety equipment.
This does not replace the need for on-
site engineering.

Advertisement

Table of Contents
loading