Intended use

The appliance is intended solely for installation and
operation in sealed unvented heating systems that
comply with EN 12828, with due attention paid to
CECS215-2017 and the associated installation, serv-
ice and operating instructions. It is only designed for
heating up heating water that is of potable water qual-
ity.
Intended use presupposes that a fixed installation in
conjunction with permissible, system-specific compo-
nents has been carried out.
Commercial or industrial usage for a purpose other
than heating the building or DHW shall be deemed
inappropriate.

Product information

Vitodens 111-W, type B1LF

Gas condensing storage combi boiler with Inox-Radial
heat exchanger and the following integrated compo-
nents:
Modulating MatriX-Plus burner for natural gas and
LPG
Stainless steel loading cylinder, 46 l capacity
Hydraulics with 3-way diverter valve and variable
speed high efficiency circulation pump
Weather-compensated or constant temperature con-
trol unit
Integral diaphragm expansion vessel (10 l capacity)

System examples

System examples with hydraulic and electrical connec-
tion diagrams and function descriptions are available
to help setting up the heating system.

Maintenance parts and spare parts

Maintenance parts and spare parts can be identified and ordered directly online.
Any usage beyond this must be approved by the man-
ufacturer in each individual case.
Incorrect usage or operation of the appliance (e.g. the
appliance being opened by the system user) is prohibi-
ted and will result in an exclusion of liability. Incorrect
usage also occurs if the components in the heating
system are modified from their intended use (e.g. if the
flue gas and ventilation air paths are sealed).
The selected gas category in the delivered condition
and the associated nominal gas pressure are given on
the boiler type plate. The type plate also shows the
other gas types and pressures with which the boiler
can be operated. A conversion within the stated natu-
ral gas groups is not required. For conversion to LPG
(without conversion kit), see "Commissioning, inspec-
tion and maintenance".
The Vitodens 111-W may only be delivered to coun-
tries listed on the type plate. For deliveries to other
countries, approved contractors must arrange individ-
ual approval on their own initiative and in accordance
with the law of the country in question.
Detailed information regarding system examples:
www.viessmann-schemes.com