Installation sequence
Power supply
Connection type BWC-M 201.A (230 V~)
A
3
kWh
1/N
D
Diagram excluding fuses and RCD.
A Heat pump control unit
B Instantaneous heating water heater
(accessory)
C Compressor (fan is directly linked to
the compressor power supply)
D High tariff meter
56
(cont.)
X3.7
X3.6
E
F
G
B
C
7
kWh
1/N
H
E Ripple control receiver (contact
open: power-OFF enabled)
F Backup fuse ripple control receiver
G TNC system feed
H Economy tariff meter
3