Viessmann VITOCAL 200-G Installation And Service Instructions Manual page 70

Type bwc & bwc-m 201.a06 to a17, 6 to 17 kw single stage heat pump with electric drive, 400 v~ & type bwc-m 201.a06 to a10, 6 to 10 kw single stage heat pump with electric drive, 230 v~
Table of Contents

Advertisement

Commissioning, inspection, maintenance
Further details regarding the individual steps
Pumps and other components
Pump/component
Heating circuit pump
Extension kit with mixer
for heating circuit M2
Circulation pump for cyl-
inder heating
DHW circulation pump
Circulation pump for
DHW reheating
Solar thermal system
70
Parameter
"System definition" Ó
"System scheme 7000"
"System definition" Ó
"System scheme 7000"
"System definition" Ó
"System scheme 7000"
"Internal hydraulics" Ó
"Enable 3-way diverter
valve heating/DHW
730D"
Extended menu:
"Time prog. DHW circ."
"Ext. heat source" Ó
"Enable external heat
source 7B00"
"Ext. heat source" Ó
"Enable external heat
source for DHW heating
7B0D"
"Solar" Ó
"Type solar control unit
7A00"
(cont.)
Setting
■ With heating circuit A1 (for
heating circuit without
mixer A1)
or
■ With heating circuit M2
(for heating circuit with
mixer M2)
With heating circuit M2
Note
Set rotary switch S1 in the
extension kit to "2" (see ex-
tension kit installation in-
structions).
With DHW heating
"0"
Setting a time program
"1"
"1"
■ "1" (with Vitosolic 100)
■ "2" (with Vitosolic 200)

Advertisement