Type bwc & bwc-m 201.a06 to a17, 6 to 17 kw single stage heat pump with electric drive, 400 v~ & type bwc-m 201.a06 to a10, 6 to 10 kw single stage heat pump with electric drive, 230 v~
Table of Contents

Advertisement

Specification
Specification
Type BWC-M 201.A
Heating water (secondary
circuit)
Capacity
Min. flow rate (spread 10 K)
Residual head (at min. flow
rate)
Max. flow temperature
Electrical values, heat
pump
Rated voltage, compressor
Rated current, compressor
Starting current, compressor
(with starting current limiter,
not for type BWC 201.A06)
Starting current, compressor
with stalled armature
Compressor fuse
Power consumption:
■ Primary pump
■ Secondary pump
■ Circulation pump for cylin-
der heating
Safety category
Electrical values, control
unit
Rated voltage
Fuse protection
Fuses
Max. power consumption
Power consumption in opera-
tion
Refrigerant circuit
Refrigerant
Refrigerant charge
Compressor
104
(cont.)
l
l/h
mbar
kPa
°C
A
A
A
A
W
W
W
W
W
kg
Type
06
1.1
520
630
63
60
1/N/PE 230 V/50 Hz
16.0
< 45
58.0
B20A
1-pole
10 to 55
10 to 55
62 to 132
I
1/N/PE 230 V/50 Hz
2 x 6.3 A H (slow)/250 V
1000
5
R410A
1.2
Hermetic
Hermetic
scroll
scroll
08
1.4
660
600
60
60
17.1
< 45
67.0
B20A
1-pole
10 to 55
10 to 55
10 to 55
10 to 55
62 to 132
62 to 132
I
B16A
1000
1000
5
5
R410A
1.45
Hermetic
scroll
10
1.9
850
580
58
60
23.0
< 45
97.0
B25A
1-pole
I
R410A
1.7