Possible Error Messages on Firmware Update Failure:

Error Message
Firmware Package Checksum Error
System Is Busy
Firmware Is Not Modified
Customized AA Prompts Backup & Restore:
Up to 10 individual prompts may be recorded through the device IVR interface (see Telephone-IVR-Based Local
Configuration section). These prompts may be backed up into a single file from the web browser. The default name of the
file is "backupaa.dat". The backup file also includes the anotations entered for each recorded prompt.
To restore an AA prompt file onto an OBi, do it exactly like a firmware upgrade via the web browser but provide the device
with the prompt file instead of a firmware file. The OBi can detect from the file header that you are trying to upload a
prompt file and process the file accordingly. Warning: All the existing prompts in the device will be removed first when
applying the backup file; this process cannot be undone.
Configuration Backup & Restore:
The current configuration of the OBi device can be backed up and stored as a file in XML format at a user specified location.
The default name of the file is "backupxxxxxxxxxxxx.xml", where the xxxxxxxxxxxxxx represents the MAC address of unit.
When backing up a device's configuration, you may select the following three options before selection of the "Backup".
Option
Incl. Running Status
Incl. Default Value
Use OBi Version
When the file browser window pops up for, you can change the filename and choose the location to save the backup file.
Note that different web browser might handle this differently. If the operation is blocked due to the security setting of the
web browser, you should change the security setting temporarily to allow this operation to complete.
When restoring the configuration to a previous backup copy, you will need to specify the backup file you want to restore to
by selecting the "Browse" button in the Restore Configuration section of the web page. Then, select the "Restore" button to
start the process. The OBi device will automatically reboot, after the restoration is complete.
Description
A corrupted Firmware package file has been used for the
update.
The OBi device is busy because one of the phone
services is in an active call or device provisioning is in
progress.
The OBi device is already running the same firmware as
the one selected for update.
Description
If checked, the value of all status parameters will be included in
backup file. Otherwise, status parameters are excluded from the
backup
If checked, the default value of parameters will be included in the
backup file. Otherwise, default values are excluded from the
backup
If not checked, the backup file uses XML tags that are compliant
with TR-104 standard. Otherwise, the backup file will be stored in
an OBi proprietary format where the XML tags are not compliant
with TR-104; but the file size will be smaller and the file will be
more readable
Copyright 2010-2012 Obihai Technology, Inc.
Suggested Solution
Check the file and / or re-
download the firmware
package and try again.
Try to update again later
No need to upgrade.
Default Setting
No
No
No
42

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Obi100Obi202Obi302

Table of Contents