NMEA PORT TEST
Loopback NMEA1
OK
Loopback NMEA2
FAIL
Note !
SYSTEM DATA
NMEA DATA
NMEA PORT TEST

Master reset?

Warning:
Will restore factory
settings. New setup
will be required
No
Yes
SYSTEM DATA
NMEA DATA
NMEA PORT TEST
Turn CCW
Warning:
Will restore factory
settings. New setup
will be required
20222410 / B
NMEA Signal Monitor
Near the NMEA terminals in the junction unit you will find a
green monitor LED (Refer to Distribution Unit Terminals, page
17). A flickering LED indicates that a NMEA signal is received.
It does not, however, qualify the contents of the message.
Do not confuse this "RX" LED with the LED marked "TX". The
"TX" LED will always be lit/flickering when the autopilot is on.

NMEA Port Test (JD5X hardware)

Disconnect the cables on the Main PCB in the distribution unit
and connect TX1+ to RX1+ and TX1– to RX1–. Similarly, on
the Power PCB, connect the NMEA ports the same way: TX2+
to RX2+ and TX2– to RX2–.
Under SERVICE in the Installation Menu, select "NMEA PORT
TEST" by pressing the
rotating the course knob clockwise.
Verify that the hardware is OK. If not, replace the corresponding
PCB('s).
Master Reset
A Master Reset will reset the memories to factory settings.
Unless you need to clear all stored values during the installation
set-up procedure, you should not perform a Master Reset. A
Master reset will not clear the stored compass calibration and
offset values in RC25, RFC35, JD5X and GI51.
The Master Reset needs a double confirmation to prevent an
accidental reset. To perform a Master Reset, rotate the course
knob clockwise and then rotate the course knob counter-
clockwise.
Exit the Installation Menu by pressing the
return to normal AP50 operation.
Advanced Settings
(STBD) button and confirm this by
STBY
(STBY) button to
81