Camera And Ip Setup Serial Commands - Microscan EZ Match Imager User Manual

Barcode scanner
Hide thumbs Also See for EZ Match Imager:
Table of Contents

Advertisement

Camera and IP Setup Serial Commands

Image Processing Timeout
IP Threshold
Mirrored Image
Window of Interest
Hollow Mode
Number of Symbols in Field of View <K518,number of symbols in field of view>
Damaged Symbol Status
Focal Distance (Read-Only)
Focal Distance Table (Read-Only)
IP Mode
Tube/Cap Mode
Illumination Brightness
Skew Correction
Camera Settings
Pixel Sub-Sampling
Color Processing
Color Detection
EZ Match User's Manual
<K245,image processing timeout>
<K512,threshold mode,fixed threshold value,cycle
min,cycle max,cycle step,adaptive contrast percent>
<K514,mirrored image>
<K516,row pointer,column pointer,row depth,column
width>
<K517,hollow mode status>
<K519,damaged symbol status>
<K525,focal distance>
<K526,number of focal distances,focal distance>
<K527,IP Mode,FLM direction>
<K533,tube/cap direction,tube/cap rotation,cap
unknown qualify,tube/cap presence before output,cap
unknown presence before output>
<K536,brightness>
<K537,line speed,symbol direction>
<K541,shutter speed,gain>
<K542,sub-sampling>
<K543,color filter>
<K544,status,color match resolution>