Advertisement

Field Service Ver1.0 Jun.2005
4.4
Adjustment to prevent false detection by the original count sensor
(PS310), original size sensors /Rt (PS302) and /Lt (PS303)
When false detection is made by the original count sensor (PS310) and the original size sensors /Lt (PS303) and
/Rt (PS302) above the original feed tray due to the angle of incident of external light such as a fluorescent light,
change the installation angle of the sensor.
A. Procedure
[2]
[1]
[6]
[1]
[5]
[3]
[3]
15saf3c005na
[2]
[3]
[4]
[2]
[4]
15saf3c006na
4. MECHANICAL ADJUSTMENT
1. Raise the original feed tray [1].
2. Remove 3 screws [2] and then remove the original
feed tray cover /Lw [3].
3. Expand the claw [1] a little wider and remove the
original size sensors /Rt (PS302) [2] and /Lt
(PS303) [3] and the original count sensor (PS310)
[4].
Note
• Be careful not to spread the claw [1] too wide.
Otherwise, it may break off.
4. Remove 2 screws [5] and then remove the sensor
holder [6].
37