Remote Controller Operation - Mitsubishi Electric Mr.Slim PAR-30MAA Technical Manual

Ma remote controller
Hide thumbs Also See for Mr.Slim PAR-30MAA:
Table of Contents

Advertisement

2. 2-remote Controller Operation

2-1. 2 Wired Remote Controllers
Slim Air Conditioners System
Outdoor unit OC
Indoor unit IC
Wired remote
System diagram
controller R
(Wired remote
controller)
Outdoor unit OC
Indoor unit IC
Wired remote
controller R
Slim Air Conditioners System
Outdoor unit OC
Indoor unit IC
Wired remote
System diagram
controller R
(Wired remote
controller)
Outdoor unit OC
Indoor unit IC
Wired remote
controller R
<Reference>
1) If simultaneous twin or triple or quad, connect the remote controller to any one of the indoor units. All functions of the indoor
unit can becontrolled even if different models (different types) are mixed.
2) Do not use crossover wiring among indoor units with simultaneous twin, triple, quad units. (Prohibited item.)
3) Set one of the remote controllers as the main controller (initial setting) and the other as the sub controller using the remote
controller's function selection.
2-2. 1 Wired and 1 Wireless Remote Controller
Slim Air Conditioners System
Outdoor unit OC
System diagram
(Wired remote
Indoor unit IC
controller and
Wired remote
wireless remote
controller
controller receiver)
Receiver R·R'
Slim Air Conditioners System
Outdoor unit OC
System diagram
(Wired remote
Indoor unit IC
controller and
Wired remote
wireless remote
controller
controller receiver)
Receiver R·R'
<Reference>
1) If simultaneous twin or triple or quad, connect both the wired remote controller and wireless remote controller receiver to
any one of the indoor units. All the functions of the indoor unit can be controlled even if different models (different types) are
mixed.
2) Do not use crossover wiring among indoor units with simultaneous twin, triple, quad units. (Prohibited item.)
3) When using 2 or more remote controllers, the display contents on the remote controllers may differ from the actual settings,
since the operation mode last by any of the wireless remote controllers will be effective.
82
Standard 1:1
OC
Indoor/outdoor
3(2)
connection cable
IC
Remote
2
controller
2
cable
R-1
R-2
OC
3(2)
IC
2
2
R-1
R-2
Simultaneous Triple
OC
3(2)
3(2)
3(2)
IC-1
IC-2
IC-3
2
2
R-1
R-2
OC
3(2)
3(2)
3(2)
IC-1
IC-2
IC-3
2
2
R-1
R-2
* Numbers given in ( ) apply when power is supplied to the indoor and outdoor units separately.
(R: Wired remote controller, R': Wireless remote controller receiver)
Standard 1:1
OC
Indoor/outdoor
connection cable
3(2)
Receiver
IC
Remote
connection
controller
cable
9
2
cable
R
R'
Simultaneous Triple
OC
3(2)
3(2)
3(2)
IC-1
IC-2
IC-3
9
2
R
R'
* Numbers given in ( ) apply when power is supplied to the indoor and outdoor units separately.
(R: Wired remote controller)
Simultaneous Twin
OC
3(2)
3(2)
IC-1
IC-2
2
2
R-1
R-2
OC
3(2)
3(2)
IC-1
IC-2
2
2
R-1
R-2
Simultaneous Quad
OC
3(2) 3(2)
3(2)
3(2)
IC-1
IC-2
IC-3
IC-4
2
2
R-1
R-2
OC
3(2)
3(2)
3(2)
3(2)
IC-1
IC-2
IC-3
IC-4
2
2
R-1
R-2
Simultaneous Twin
OC
3(2)
3(2)
IC-1
IC-2
9
2
R
R'
Simultaneous Quad
OC
3(2) 3(2)
3(2)
3(2)
IC-1
IC-2
IC-3
IC-4
9
2
R
R'

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents