Main menu list

Setting and display items
Vane ∙ Louver ∙ Vent.
(Lossnay)
High power
Timer
On/Off timer
Auto-Off
timer
Filter information
Error information
Weekly timer
Energy
Auto return
saving
Schedule
Night setback
Restriction
Temp. range Use to restrict the preset temperature range.
Operation
lock
Maintenance Auto
descending
panel
Manual
vane angle
Initial setting Main/Sub
Clock
Main display Use to switch between "Full" and "Basic" modes for the Main display.
Contrast
12
Use to set the vane angle.
• Select a desired vane setting from five different settings.
Use to turn ON / OFF the louver.
• Select a desired setting from "ON" and "OFF."
Use to set the amount of ventilation.
• Select a desired setting from "Off," "Low," and "High."
Use to reach the comfortable room temperature quickly.
• Units can be operated in the High-power mode for up to 30 minutes.
Use to set the operation On/Off times.
• Time can be set in 5-minute increments.
* Clock setting is required.
Use to set the Auto-Off time.
• Time can be set to a value from 30 to 20 in 10-minute increments.
Use to check the filter status.
• The filter sign can be reset.
Use to check error information when an error occurs.
• Error code, error source, refrigerant address, unit model, manufacturing number,
contact information (dealer's phone number) can be displayed.
* The unit model, manufacturing number, and contact information need to be
registered in advance to be displayed.
Use to set the weekly operation On / Off times.
• Up to eight operation patterns can be set for each day.
* Clock setting is required.
* Not valid when the On/Off timer is enabled.
Use to get the units to operate at the preset temperature after performing
energy-save operation for a specified time period.
• Time can be set to a value from 30 and 120 in 10-minute increments.
* This function will not be valid when the preset temperature ranges are restricted.
Set the start/stop times to operate the units in the energy-save mode for each
day of the week, and set the energy-saving rate.
• Up to four energy-save operation patterns can be set for each day.
• Time can be set in 5-minute increments.
• Energy-saving rate can be set to a value from 0% and 50 to 90% in 10% increments.
* Clock setting is required.
Use to make Night setback settings.
• Select "Yes" to enable the setting, and "No" to disable the setting. The temperature
range and the start/stop times can be set.
* Clock setting is required.
• Different temperature ranges can be set for different operation modes.
Use to lock selected functions.
• The locked functions cannot be operated.
Auto descending panel (Optional parts) Up / Down you can do.
Use to set the vane angle for each vane to a fixed position.
When connecting two remote controllers, one of them needs to be designated
as a sub controller.
Use to set the current time.
• The default setting is "Full."
Use to adjust screen contrast.
Setting details
Reference
page
19
21
22
2
26
28
30
32
3
36
38
0
1
2

5
6
7