2. Two-Remote Controller Operation

2.1 When Two Wired Remote Controllers are Used

Slim Air Conditioner System
Outdoor unit
OC
Indoor unit IC
Remote
Wired remote
controller
controller R
connection
circuit
Outdoor unit
(Controller
OC
cable)
Indoor unit IC
Wired remote
controller R
[Reference]
1 In the case of free component multi type systems consisting of simultaneous twin, triple and quad units, connect the remote controllers to any
one of the indoor units. All the functions of the connected indoor units can be controlled even if the system consists of different models. However,
some functions may be restricted.
2 In the case of free component multi type systems consisting of simultaneous twin, triple and quad units, the indoor units should not be connected
by crossover wiring. (Prohibited)
3 Set one of the remote controllers as the main controller (factory setting) and the other as the sub controller using the remote controller's function
selection.

2.2 When Two Wireless Remote Controllers are Used

Slim Air Conditioner System
Outdoor unit
Remote
OC
controller
receiver
Indoor unit IC
connection
circuit
Wired remote
controller R
[Reference]
1 In the case of free component multi type systems consisting of simultaneous twin, triple and quad units, connect two wireless remote controller
receivers (one each) to any two of the indoor units. All the functions of the connected indoor units can be controlled even if the system consists
of different models. However, some functions may be restricted.
2 In the case of free component multi type systems consisting of simultaneous twin, triple and quad units, the indoor units should not be connected
by crossover wiring. (Prohibited)
3 In the case of "standard 1:1" connection, it is not possible to connect two remote controller receivers to the indoor units. However, with systems
consisting of simultaneous twin, triple and quad units, it is possible to connect a remote controller receiver to two indoor units. In this case, all
the pair numbers will be "0" (factory setting, no change necessary), and all the units will be turned ON/OFF simultaneously.
4 When using two or more wireless remote controllers, the display contents on the remote controllers may differ from the actual settings, since the
operation made last by any of the remote controllers will be effective.

2.3 When One Wired and One Wireless Remote Controller are Used

Slim Air Conditioner System
Outdoor unit
Remote
OC
controller
receiver
Indoor unit IC
connection
circuit
Wired remote
controller R
[Reference]
1 In the case of free component multi type systems consisting of simultaneous twin, triple and quad units, connect both the wired remote controller
and wireless remote controller receiver to any one of the indoor units. All the functions of the connected indoor units can be controlled even if
the system consists of different models. However, some functions may be restricted.
2 In the case of free component multi type systems consisting of simultaneous twin, triple and quad units, the indoor units should not be connected
by crossover wiring. (Prohibited)
3 When using two or more wireless remote controllers, the display contents on the remote controllers may differ from the actual settings, since the
operation made last by any of the wireless remote controllers will be effective.
Standard 1:1
OC
Indoor/outdoor
3(2)
connection cable
IC
Remote
2
2
controller
cable
R-1
R-2
OC
3(2)
IC
2
2
R-1
R-2
* Numbers given in ( ) apply when power is supplied to the indoor and outdoor units separately.
Standard 1:1
Indoor/outdoor
connection cable
* Numbers given in ( ) apply when power is supplied to the indoor and outdoor units separately.
Standard 1:1
OC
Indoor/outdoor
3(2)
connection cable
IC
Receiver
Remote
connection
9
controller
2
cable
cable
R
R'
* Numbers given in ( ) apply when power is supplied to the indoor and outdoor units separately.
(R: Wired remote controller, R': Wireless remote controller receiver)
Simultaneous Twin
Simultaneous Triple
OC
OC
3(2)
3(2)
IC-1
IC-2
IC-1
2
2
R-1
R-2
R-1
OC
OC
3(2)
3(2)
IC-1
IC-2
IC-1
2
2
R-1
R-2
R-1
Simultaneous Twin
Simultaneous Triple
OC
OC
3(2)
3(2)
IC-1
IC-2
IC-1
Receiver
9
9
connection
cable
R'-1
R'-2
R'-1
(R: Wired remote controller, R': Wireless remote controller receiver)
Simultaneous Twin
Simultaneous Triple
OC
OC
3(2)
3(2)
IC-1
IC-2
IC-1
9
2
R
R'
R
Simultaneous Quad
OC
3(2) 3(2)
3(2)
3(2)
3(2)
IC-2
IC-3
IC-1
2
2
2
R-2
R-1
OC
3(2)
3(2)
3(2)
3(2)
IC-2
IC-3
IC-1
2
2
2
R-2
R-1
Simultaneous Quad
OC
3(2)
3(2) 3(2)
3(2)
3(2)
IC-2
IC-3
IC-1
9
9
9
R'-2
R'-1
Simultaneous Quad
OC
3(2)
3(2) 3(2)
3(2)
3(2)
IC-2
IC-3
IC-1
9
2
2
R'
R
3(2)
3(2)
IC-2
IC-3
IC-4
2
R-2
3(2)
3(2)
3(2)
IC-2
IC-3
IC-4
2
R-2
3(2)
3(2)
IC-2
IC-3
IC-4
9
R'-2
3(2)
3(2)
IC-2
IC-3
IC-4
9
R'