[ 5 ]
Function setting
Ref. address
Grp.
Sending data
<Table1> Function setting options
Mode
Mode
No.
01
Automatic recovery after
power failure
02
Thermistor selection
(indoor temperature
detection)
03
LOSSNAY connection
0
Power voltage
05
AUTO mode
07
Filter sign
08
Fan speed
09
Outlet
10
Optional parts
(High-efficiency filter)
11
Vane
When the settings are completed, press the
data from the remote controller to the indoor units.
When the transmission is successfully completed, the screen will return to the
Function setting screen.
note: • Make the above settings only on Mr. Slim units as necessary.
• The above function settings are not available for the City Multi
units.
• Table 1 summarizes the setting options for each mode number.
Refer to the indoor unit Installation Manual for the detailed infor-
mation about initial settings, mode numbers, and setting num-
bers for the indoor units.
• Be sure to write down the settings for all functions if any of the
initial settings has been changed after the completion of installa-
tion work.
Settings
Disable
Enable (Four minutes of standby time is
required after the restoration of power.)
Average temperature reading of the indoor
units in operation
Thermistor on the indoor unit to which the
remote controller is connected (fixed)
Built-in sensor on the remote controller
Not connected
Connected (without outdoor air intake by
the indoor units )
Connected (with outdoor air intake by the
indoor units )
20 V
220 V, 230 V
Enable (Automatically the unit achieves ef-
fective energy saving operation.)
Disable
100 hours
2500 hours
Not displayed
Silent mode (or standard)
Standard (or High ceiling 1)
High ceiling (or High ceiling 2)
 directional
3 directional
2 directional
No
Yes
No vanes
(or the vane setting No.3 is effective.)
Equipped with vanes
(The vane setting No.1 is effective.)
Equipped with vanes
(The vane setting No.2 is effective.)
button to send the setting
Setting
Unit numbers
No.
1
Set "Grp." for the Unit number.
These settings apply to all the con-
2
nected indoor units.
1
2
3
1
2
3
1
2
1
2
1
Set "1, 2, 3, , or All" for the Unit
number.These settings apply to each
2
indoor unit.
3
• If "1, 2, 3, or " is set for the Unit
number, the settings apply only to
1
the specified indoor unit regardless
2
of the number of connected indoor
units (one through four units).
3
• If "ALL" is set for the Unit number,
1
the settings apply to all the connect-
2
ed indoor units regardless of the
number ofconnected indoor units
3
(one through fourunits).
1
2
1
2
3