Removal Of Heat Exchanger - Daikin F-Series Service Manual

F-series inverter pair wall mounted type
Hide thumbs Also See for F-Series:
Table of Contents

Advertisement

Si04-703A
1.5
Removal of
Procedure
Step
Remove the electrical
box.
1. Disconnect the refrigerant
piping.
Hold the indoor unit up
1
by a piece of wood etc.
2
Unscrew the flare nut
for
gas piping
by 2
wrenches.
Unscrew the flare nut
3
for
liquid piping
by 2
wrenches.
Removal Procedure
Heat Exchanger
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Indoor Unit
Points
Caution
If gas leaks, repair the spot of
leaking, then collect all
refrigerant from the unit. After
conducting vacuum drying,
recharge proper amount of
refrigerant.
Caution
Do not contaminate any gas
(including air) other than the
specified refrigerant (R-410A)
into refrigerant cycle.
(Contaminating of air or other
gas causes abnormal high
pressure in refrigerating
cycle, and this results in pipe
breakage or personal
injuries.)
Pay attention so that the
residual water in the drain
will not make the floor wet.
In case that a
drain hose
buried inside a wall, remove
it after the drain hose in the
wall is pulled out.
Use 2 wrenches to
disconnected pipes.
When disconnecting pipes,
cover every nozzle with caps
so as not to let dust and
moisture in.
is
153

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents