Removal Of Indoor Heat Exchanger - Daikin FVXD60FV2CW Service Manual

Table of Contents

Advertisement

Si06-760

9. Removal of Indoor Heat Exchanger

Procedure
Step
1. Detach the indoor heat
exchanger.
Detach the front panel.
Detach the electrical box.
Release the harnesses
from the hook behind the
electrical box.
1
Pull out the air outlet
guide.
2
Remove the screw and
remove the piping
cover.
3
Remove the piping
fixture.
4
Release the harnesses
(indoor heat exchanger
thermistor, earth wire)
from the ditch of the
drain pan.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Air outlet guide
Harnesses
Piping cover
Removal of Indoor Heat Exchanger
(R18541)
Piping fixture
(R10254)
Points
17