Daikin F-Series Service Manual page 25

F-series inverter pair wall mounted type
Hide thumbs Also See for F-Series:
Table of Contents

Advertisement

Specifications
Indoor Units
Model
Outdoor Units
Capacity
Rated (Min.~Max.)
Running Current Rated
Power Consumption
Rated (Min.~Max.)
Power Factor
COP
Rated (Min.~Max.)
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Max. Interunit Piping Length
Max. Interunit Height Difference
Chargeless
Amount of Additional Charge of
Refrigerant
Indoor Unit
Front Panel Color
m³/min
Airflow Rate
(cfm)
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Outdoor Unit
Casing Color
Type
Compressor
Model
Motor Output
Type
Refrigerant Oil
Charge
Type
Refrigerant
Charge
Airflow Rate
m³/min (cfm)
Type
Fan
Motor Output
Running Current (Rated)
Power Consumption (Rated)
Power Factor (Rated)
Starting Current
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/SL
Sound
Drawing No.
Note:
14
FTKS50FVLT
RKS50FVLT
kW
5.0 (1.7~6.0)
Btu/h
17,100 (5,800~20,500)
kcal/h
4,300 (1,460~5,160)
A
7.2
W
1,550 (440~2,080)
%
97.9
W/W
3.23 (3.86~2.88)
φ
mm
6.4
φ
mm
12.7
φ
mm
18.0
Both Liquid and Gas Pipes
m
30
m
20
m
10
g/m
20
FTKS50FVLT
White
H
14.7 (519)
M
12.4 (438)
L
10.3 (364)
SL
9.5 (335)
Cross Flow Fan
W
43
Steps
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable/Washable/Mildew Proof
A
0.16
W
34
%
96.6
Microcomputer Control
mm
290×1,050×238
mm
337×1,147×366
kg
12
kg
17
dBA
43/39/34/31
RKS50FVLT
Ivory White
Hermetically Sealed Swing Type
2YC36BXD
W
1,100
FVC50K
L
0.65
R-410A
kg
1.50
HH
50.9 (1,797)
H
48.9 (1,727)
L
41.7 (1,472)
Propeller
W
53
A
7.04
W
1,516
%
97.9
A
7.2
mm
735×825×300
mm
792×960×390
kg
47
kg
52
dBA
47/44
3D056228
The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
FTKS60FVLT
RKS60FVLT
5.85 (1.7~6.7)
20,000 (5,800~22,900)
5,030 (1,460~5,760)
9.6
2,080 (440~2,400)
98.5
2.81 (3.86~2.79)
φ
6.4
φ
12.7
φ
18.0
Both Liquid and Gas Pipes
30
20
10
20
FTKS60FVLT
White
16.2 (572)
13.6 (480)
11.4 (403)
10.2 (360)
Cross Flow Fan
43
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable/Washable/Mildew Proof
0.19
40
95.7
Microcomputer Control
290×1,050×238
337×1,147×366
12
17
45/41/36/33
RKS60FVLT
Ivory White
Hermetically Sealed Swing Type
2YC36BXD
1,100
FVC50K
0.65
R-410A
1.50
54.2 (1,914)
50.9 (1,797)
45.0 (1,589)
Propeller
53
9.41
2,040
98.5
9.6
735×825×300
792×960×390
47
52
49/46
3D056229
Piping Length
7.5m
Si04-703A
60Hz 220V
FTKS71FVLT
RKS71FVLT
7.6 (2.3~8.3)
25,900 (7,800~28,300)
6,540 (1,980~7,140)
13.8
3,010 (570~3,580)
99.1
2.52 (4.04~2.32)
φ
6.4
φ
15.9
φ
18.0
Both Liquid and Gas Pipes
30
20
10
20
FTKS71FVLT
White
17.4 (614)
14.6 (516)
11.6 (410)
10.6 (374)
Cross Flow Fan
43
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable/Washable/Mildew Proof
0.21
45
97.4
Microcomputer Control
290×1,050×238
337×1,147×366
12
17
46/42/37/34
RKS71FVLT
Ivory White
Hermetically Sealed Swing Type
2YC63BXD
1,920
FVC50K
0.75
R-410A
1.70
59.4 (2,097)
59.4 (2,097)
46.3 (1,635)
Propeller
53
13.59
2,965
99.2
13.8
735×825×300
792×960×390
55
61
53/49
3D056230
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Specifications

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents