System
Indoor
Unit
Outdoor
Unit
Service Diagnosis
Code Indication Description
00
Normal
U0★
Insufficient gas
U2
Low-voltage detection or over-voltage detection
U4
Signal transmission error (between indoor and outdoor units)
A1
Indoor unit PCB abnormality
A5
Freeze-up protection control or high pressure control
A6
Fan motor or related abnormality
C4
Heat exchanger thermistor abnormality
C9
Room temperature thermistor abnormality
E1
Outdoor unit PCB abnormality
E5★
OL activation (compressor overload)
E6★
Compressor lock
E7
DC fan lock
E8
Input over current detection
EA
Four Way Valve Abnormality
F3
Discharge pipe temperature control
F6
High Pressure Control in Cooling
H0
Sensor abnormality
H6
Position sensor abnormality
H8
CT or related abnormality
H9
Outdoor air thermistor or related abnormality
J3
Discharge pipe thermistor or related abnormality
J6
Heat exchanger thermistor or related abnormality
L3
Electrical box temperature rise
L4
Radiation fin temperature rise
L5
Output over current detection
P4
Radiation fin thermistor or related abnormality
U7
Signal transmission error
: Displayed only when system-down occurs.

Troubleshooting

Reference
Page
126
128
100
94
95
97
99
99
102
103
104
105
106
108
110
111
113
115
116
118
118
118
120
122
124
118
129
93

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents