Specifications Of Electrical Parts - Toshiba Carrier RAS-12EKCV-UL Service Manual

Split type
Table of Contents

Advertisement

6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
No.
Parts name
RAS-09EKCV-UL
Fan motor
1
(for indoor)
RAS-12EKCV-UL
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Louver motor
6-2. Outdoor Unit
No.
Parts name
1
Reactor
Outdoor fan motor
2
3
Suction temp. sensor (TS sensor)
4
Discharge temp. sensor (TD sensor)
5
Outside air temp. sensor (TO sensor)
6
Heat exchanger temp. sensor (TE sensor)
7
Terminal block (5P)
RAS-09EACV-UL
8
Compressor
RAS-12EACV-UL
9
COIL FOR P.M.V.
10
Coil for 4-way valve
11
Pressure SW.
Type
AFN-220-20-4D
ICF-340U30-2
DC 340, 30W
( − )
10k
(
)
10kΩ at 25°C
24BYJ48-HTP
Output (Rated) 1W, 16 poles, DC12V
Model name
CH-57-Z-T
ICF-340UA40-2
DC340V, 40W
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
3-phases 4-poles 680W
DA89X1C-23FZ2
3-phases 4-poles 750W
DA111A1F-20F2
CAM-MD 12TCTH-4
STF-01AQ503UC1
ACB-4UB82W
– 20 –
FILE NO. SVM-13071
Specifications
AC240V, 20W
at 25°C
Rating
L = 10mH, 16A
10kΩ (25°C)
62kΩ (20°C)
10kΩ (25°C)
10kΩ (25°C)
30A, AC600V
DC12V
4.7 MPa