One-Touch Comfort; Hi-Power Mode - Toshiba Carrier RAS-12EKCV-UL Service Manual

Split type
Table of Contents

Advertisement

Item
18. One-Touch
One touch comfort is the fully automated operation
Comfort
that is set according to the preferable condition in
a region.
Fan
Operation
*Hi-POWER/AUTO: Fan operates depends on the
setting temperature and room temperature.
During the One Touch Comfort mode if the indoor
unit receives any signal with other operation mode,
the unit will cancel the comfort mode and operates
according to the signal received.
19. Hi-POWER
([Hi-POWER] button on the remote controller
Mode
is pressed)
When [Hi-POWER] button is pressed while the indoor
unit is in Auto or cooling operation, Hi-POWER mark
is indicated on the display of the remote controller and
the unit operates as follows.
1. Automatic operation
2. Cooling operation
3. The Hi-POWER mode can not be set in Dry
Operation flow and applicable data, etc.
* Hi-POWER/
Hi-POWER
AUTO
0
12
25
• The indoor unit operates in according to the
current operation.
• The preset temperature drops 1ºC [2°F]
(The value of the preset temperature on the
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
operation
When an indoor unit receives "One Touch
Comfort Signal" from the remote controller,
the indoor unit operates as following.
AUTO
Time after operation
starts (min)
41
FILE NO. SVM-13071
Description
1) Air conditioner starts to operation when
the signal is received, even if the air
conditioner was OFF.
2) Target temperature is 22ºC [72°F].
3) Louver position is set as swing position.
4) Fan is controlled as followings.
.

Hide quick links: