4. System Controller
D:
ON button
E:
OFF button
F:
Operation lamp
G:
MODE button
H: Temperature setting
buttons
I:
FAN SPEED button
J: FLAP button
This button is for turning the selected air conditioner on.
This button is for turning the selected air conditioner off.
This lamp lights when the unit is turned on.
Use this button to select one of the following 5 operations:
(AUTO)
:
Used to automatically set cooling or heating operation.
Only for heat pump type
(HEAT)
: Used for normal heating operation.
Only for heat pump type
(DRY)
: Used for dehumidifying without changing the room temperature.
(COOL)
:
Used for normal cooling operation.
(FAN)
:
Used to run the fan only, without heating or cooling operation.
When the
NOTE
and
units once then select the mode again.
: Press this button to increase the temperature setting.
: Press this button to decrease the temperature setting.
(AUTO)
: The air conditioner automatically decides the fan speed.
(HI)
: High fan speed
(MED)
: Medium fan speed
(LO)
: Low fan speed
1.
Use this button to set the airflow direction to a specific angle.
The airflow direction is displayed on the remote control unit.
Operation mode
(COOL) or
(HEAT) or
(AUTO)
Cooling mode:
Heating mode:
In the Cool mode and Dry mode, when the flaps are set in a
CAUTION
downward position, condensation may form and drip aroun
the vent.
Do not move the flap with your hands.
NOTE
This function is available only for models X, XM, T and L types.
(
)
2.
Use this button to make the airflow direction sweep up and down
automatically.
Press this button several times until the (
the display.
NOTE
This function is available only for models X, XM, K, T and L types.
1)
The flap setting can be performed only for units that have no remote
NOTE
controllers.
2)
In the ALL or ZONE mode, no flap setting can be performed. If
necessary, you should select the GR mode and use the FLAP button.
indication is displayed, you cannot change the mode from
or
to
or
and
Number of airflow direction settings
(DRY)
(FAN)
3-49
Control of 3-WAY ECO-i SYSTEM
(Temperature range: 17 to 27°C)
(Temperature range: 16 to 26°C)
(Temperature range: 18 to 30°C)
(Temperature range: 18 to 30°C)
. To change the mode, turn off all
3
5
3
5
) symbol appears
1
2
3
4
5
6
on
7
8