Panasonic UF-585 Service Manual page 133

Hide thumbs Also See for UF-585:
Table of Contents

Advertisement

Panasonic UF-585 / 595
Code
Mode
434
XMT or RCV
436
G3 RX
456
RCV
457
RELAYXMT
CONF.XMT/
POLL
459
RCV
490
RCV
494
RCV
495
XMT/RCV
496
XMT
501
XMT/
RCV(V.34)
502
XMT/
RCV(V.34)
503
XMT/
RCV(V.34)
504
RCV/V.34
(Polling)
505
XMT/V.34
(Polling)
540
XMT ECM
541
XMT ECM
542
XMT ECM
543
XMT ECM
544
XMT ECM
550
RCV ECM
554
RCV ECM
555
RCV ECM
570
RCV
571
XMT
580
XMT
581
XMT
601
XMT
623
XMT
630
XMT or
RCV(Polling)
631
XMT
138
Information Codes
Phase
Description of Problem
B
CD (response from Modem) did not turn OFF
within 180 sec. after receiver detected FLAG
signal.
C
DCN received after transmitting FTT.
B
Received relay transfer request or confidential
document to distribute to a end receiving station
or all confidential mailboxes are used.
B
Remote unit does not have Relayed XMT or
Confidential Comm. capability.
C
Failed training in Phase C.
C
Sum of error line exceeded the limit (Parameter
70) by 64 lines.
C
Interval between two EOLs was more than 10
sec. when receiver received message data.
C
During reception, CD turned OFF or continued
ON for long time.
During communication, lost loop - current.
C
CS of modem is not able to turn ON.
B
Remote unit does not have Modem
compatibility.
B,C,D
During reception, CD turned OFF or continued
ON for long time.
During communication, lost loop - current.
B,C,D
CS of modem is not able to turn ON during
training.
B
Polling is rejected from the remote station.
B
Polling XMT is rejected.
B
No response after transmitting 3rd CTC or DCN
received.
D
No response after transmitting 3rd EOR or
received DCN.
D
No response to the 3rd RR transmitted or
received DCN.
D
T5 timer (60 sec.) elapsed without MCF.
D
Stopped Transmission after EOR Transmission. Line is faulty.
C
Timer between frames in phase C has elapsed. Defective remote station.
D
Transmitted ERR after receiving EOR.
D
Transmitted PIN after receiving EOR.
B
Password or machine code did not match during
remote diagnostic communication.
B
Remote unit did not have the remote diagnostic
function.
B
Sub-address transmission to a unit that has their
DIS bit 49 (NSF bit 155) OFF.
B
Sub-address Password transmission to a unit
that has their DIS bit 50 (NSF bit 156) OFF.
ADF Door was opened during ADF
transmission.
A
No document was in the ADF. (Built-in dialer
engaged)
B
Redial count over.
A
"STOP" button was pressed during Auto Dialing.
Cause
Remote unit is defective.
SCA/SCB PCB or LCU PCB is defective.
Transmitter is defective or incompatible.
Line quality is poor.
Line quality is poor. (Training signal is distorted
due to line noise)
SCA/SCB PCB or LCU PCB are defective.
Line quality is poor.
SCA/SCB PCB or LCU PCB are defective.
Transmitter is defective.
Line quality is poor. (EOL is damaged due to
line noise)
SCA/SCB PCB or LCU PCB are defective.
Line is disconnected.
Transmitter is defective.
SCA/SCB PCB or LCU PCB are defective.
SCA/SCB PCB is defective.
Line is disconnected.
Transmitter is defective.
SCA/SCB PCB or LCU PCB are defective.
SCA/SCB PCB is defective.
Line is disconnected.
No polling document is set.
No polling document is set.
Incompatible interface.
Line is faulty.
LCU PCB abnormal.
Remote unit is abnormal.
Remote unit is abnormal.
LCU PCB abnormal.
Faulty line.
Faulty line and Operator Call requested by RX
side.
Sub-address transmission to a unit that has no
Sub-address function.
Sub-address transmission to a unit that has no
Sub-address function.
Operator removed the document from the ADF
after dialing was completed.
Document is not set properly in the ADF.
No dial tone detected.
Sensor dial tone is not detected. (country
dependent)
Busy tone is detected. (country dependent)
T1 timer (35±5 sec) elapsed without a signal
from the receiver.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uf-595