Outdoor unit installation

caution
WARNING
Install the outdoor unit on a rigid base to prevent excessive
noise level and vibration.
Choose an outdoor unit location where the air outlet direction
is not blocked, and the clearances as per the assembly
diagram ( gure 1) are followed.
In the case that the installation location is exposed to strong
wind such as a seaside, make sure the fan can operate properly
by putting the unit lengthwise along the wall or using a dust
or shield plates. If installing on a wall bracket, the installer
must supply a suitable mounting bracket that can hold the full
weight of the product, use suitable xings to attach to the wall
and must follow the installation instructions of the wall bracket
accordingly.
The installation wall should be solid brick, concrete or the
same intensity construction, or take actions to reinforce,
support and add vibration dampening material as required.
The connection between the wall, bracket and the air
conditioner should be rm, stable and reliable.
Be sure there is no obstacle which blocks the air ow.
Fig. 9
Incorrect
Strong
wind

Location of outdoor unit

Anchor the outdoor unit with a 8 or 10 diameter bolt and nut
tightly and horizontally on a concrete or rigid mount.
Outdoor unit
Model
dimensions
W x H x D (mm)
KSV25CRH
KSV25HRH
KSD25HRH
KSV25HWH
KSD25HWH
885 x 554 x 365
KSV35CRH
KSV35HRH
KSD35HRH
KSV35HWH
KSD35HWH
KSV50HRH
KSD50HRH
924 x 702 x 382
KSV50HWH
KSD50HWH
KSV71CRH
KSV71HRH
KSD71HRH
924 x 702 x 382
KSV71HWH
KSD71HWH
KSV90HRH
KSD90HRH
1040 x 810 x 455
KSV90HWH
KSD90HWH
10 Outdoor unit installation Kelvinator Air Conditioning
Correct
Barrier
Strong
wind
Outdoor
unit
Dimensions
Dimensions
weight
A (mm)
B (mm)
(kg)
32.5
514
42.1
540
52.5
540
64.5
673

Drain elbow installation

NOTE: The drain elbow is slightly different according to the
different outdoor unit. For the drain elbow with the seal (Fig.11
(A)), rst t the seal onto the drain elbow, then insert the drain
elbow into the base pan hole of outdoor unit, rotate 90 to securely
assemble them. To install drain elbow as shown in Fig.11 (B), insert
the drain elbow into the base pan hole of outdoor unit until it
remains xed with a clicking sound.
The installer may supply and connect a drain hose to the drain
elbow to direct the condensed water to a suitable location that will
not cause damage to people or property."
In cold areas that can drop below 0°C, it is not recommended to
install a drain hose as it may be subject to freezing
Fig. 10
Air inlet
D
Fig. 11
Seal
340
(A)
350
350
403
H
W
A
Air inlet
Air outlet
Drain elbow
Base pan hole
of outdoor unit
(B)
Seal
Drain pipe