Technical Specifications

Topic
Recommended maximum input power
MPPT voltage range
Operating range
Maximum DC input voltage
Minimum / Maximum start voltage
Maximum DC input short circuit current
Maximum DC input current
Maximum AC output Power (-40 to 65 °C)
Output power factor
Nominal AC output voltage
Maximum AC output current, 230 Vac
Number of AC phases
Maximum microinverters per 20 amp AC branch circuit
230 Vac
400 Vac (three-phase)
Total Harmonic Distortion
Ambient temperature range
Operating temperature range (internal)
Storage temperature range
EN50530 weighted efficiency (EU)
Static MPPT efficiency (weighted, EN 50530)
Dynamic MPPT efficiency (weighted, EN 50530) slow
irradiation changes
Dynamic MPPT efficiency (weighted, EN 50530) fast
irradiation changes
Dynamic MPPT efficiency (weighted, EN 50530) start up
and shut down
Night Tare Loss
25
Enphase M215 Microinverter Parameters
DC Parameters
AC Parameters
Operational Data
Efficiency
Copyright © 2012 Enphase Energy
M215 Installation and Operation
Unit
Min
Typical
W
V
22
29
V
16
V
V
22
A
A
W
215
0.95
0.99
230
A
.93
1
1
%
3.0
-40
°C
-40
°C
-40
°C
%
95.4
%
99.6
%
99.3
%
99.3
%
99.8
mW
50
141-00021 Rev 01
Max
260
36
36
45
45
15
10.5
1
1
17
27
5
65
85
65