Operating Parameters; Installation - Hughes JVC CB100 User Manual

Hughes-jvc projector user's guide
Table of Contents

Advertisement

Chapter 6—System Specifications

Operating Parameters

Projection
Operating Temperature
Full Performance Range
Storage Temperature
Humidity
Heat Dissipation
Warm-up Time
Noise Level
Lamp
Light Modulator
CRT
Power Requirements
Power Consumption
Power Plug
Safety and Emission
EMI
Radiation Safety

Installation

Setting
Keystone Correction
Optical Shift Correction
Operating Angle
Size (H x W x L)
Weight
Air Flow (rear view)
Lens Options
6-2
Front or rear. Upright or downright.
10º C to 40º C (50º - 104º F).
20º C to 30º C (68º - 86º F).
-20º C to 50º C (-4º - 122º F).
10 to 90% RH (non-condensing).
4100 BTUs/hour; 1100 kcal/hour.
30 minutes for full performance; < 5 minutes for useable picture.
50 dB ("A" weighted).
750 Watt Xenon Arc Lamp.
3 Image Light Amplifiers (proprietary)
100% solid state liquid crystal light valve.
3 IR Phosphor 1.77inch.
90-132 VAC; 200-264 VAC; 50/60 Hz, 14/7A.
1250 Watts.
90 VAC ~ 132 VAC at 14 Amperes Typical;
NEMA 5-20P, 20A (plug);
NEMA 5-20R, 20A (receptacle).
200 VAC ~ 264 VAC at 7 Amperes Typical;
CEE 7/vii (plug);
CEE 7 (receptacle).
UL,CSA, TÜV(CE)
FCC Class A CISPR 22.
DHHS. Act of 1968, 21 Code of Federal Regulation [CFR],
Subchapter J.
Floor or Ceiling. Upright or Downright.
Horizontal: ± 5º left or right.
Vertical: ± 15º up or down.
50% Off-Axis Shift.
0-85º up or down.
0-5º sideways.
451 mm x 692 mm x 947 mm (15in. x 28 in. x 35 in.).
75kg (165 lbs.).
Intake at rear; exhaust at right (rear view).
Motorized Zoom 3.1 - 8.1 lens.
Fixed 1:1 Wide Angle lens—Used for short projection
distances and rear projection applications.
Fixed 1.5:1 lens with offset—Needed for ceiling mounted
applications or where wider projection angles are necessary.
Hughes-JVC Technology Corporation

Advertisement

Table of Contents
loading

This manual is also suitable for:

100