Ricoh M052 Service Manual page 620

Hide thumbs Also See for M052:
Table of Contents

Advertisement

NCU Parameters
Address
International dial tone reset time
680539
(LOW)
International dial tone reset time
68053A
(HIGH)
International dial tone continuous
68053B
tone time
International dial tone permissible
68053C
drop time
International dial wait interval
68053D
(LOW)
International dial wait interval
68053E
(HIGH)
Country dial tone upper frequency
68053F
limit (HIGH)
Country dial tone upper frequency
680540
limit (LOW)
Country dial tone lower frequency
680541
limit (HIGH)
Country dial tone lower frequency
680542
limit (LOW)
680543
Country dial tone detection time
Country dial tone reset time
680544
(LOW)
Country dial tone reset time
680545
(HIGH)
Country dial tone continuous tone
680546
time
Country dial tone permissible drop
680547
time
M381
Function
108
Unit
the pause time (68053D
/ 68053E).
Belgium: See Note 2.
-
If both addresses
contain FF(H), tone
detection is disabled.
Hz (BCD)
If both addresses
contain FF(H), tone
detection is disabled.
If 680543 contains FF,
the machine pauses for
20 ms
the pause time (680548 /
680549).
-
-
20 ms
-
Remarks
SM

Advertisement

Table of Contents
loading

Table of Contents